Por favor, use este identificador para citar o enlazar este ítem: http://repositoriodigital.ipn.mx/handle/123456789/11187
Registro completo de metadatos
Campo DC Valor Lengua/Idioma
dc.creatorESTEVEZ HERNANDEZ, O.-
dc.creatorNARANJO RODRIGUEZ, I-
dc.creatorHIDALGO HIDALGOD DE CISNEROS, J.L.-
dc.creatorREGUERA, E.-
dc.date2012-03-27T23:36:07Z-
dc.date2012-03-27T23:36:07Z-
dc.date2006-10-27-
dc.date.accessioned2013-01-16T13:19:02Z-
dc.date.available2013-01-16T13:19:02Z-
dc.date.issued2013-01-16-
dc.identifierSensors and Actuators B 123 (2007) 488–494-
dc.identifierhttp://hdl.handle.net/123456789/700-
dc.identifier.urihttp://www.repositoriodigital.ipn.mx/handle/123456789/11187-
dc.descriptionTwo series of 1-furoylthioureas (FTHD) were used as modifiers of carbon paste electrodes (CPEs) for the analysis of Cd(II). The capacities of the newly FTHD-modified CPEs were calculated and the surface reactions during the preconcentration of Cd(II) were studied by cyclic voltammetry. The analyte was accumulated on the surface of the modified CPEs by complexing with FTHD 3,3-disubstituted (series 1) and 3-monosubstituted (series 2) and reduced at a negative potential (−1.0 V). It was then quantified by differential pulse anodic stripping voltammetry (DPASV) in Britton–Robinson buffer at pH 4. Experiments were conducted to establish the optimal carbon paste composition, electrolyte and pH of the determination, accumulation potential and time, and instrumental parameters. Under the optimized working conditions good linear correlations were obtained for the calibration graphs in the concentration ranges studied. For 5 min of accumulation time, detection limits using modified CPEs with ligands of series 2 were lower than that of series 1 (6×10−5 mg L−1 versus 3×10−3 mg L−1, respectively, for the CPEs modified with 1- furoyl-3-p-tetradecylphenylthiourea and 1-furoyl-3-benzyl-3-phenylthiourea taken as models of both series). For a series of seven determinations of Cd(II) at 0.5 mg L−1 relative standard deviations below 3.9% were achieved for CPEs with ligands of both series. Only Pb(II) and Cu(II) apparently affected the electrochemical response of Cd(II). © 2006 Elsevier B.V. All rights reserved.-
dc.languageen-
dc.publisherScienceDirect-
dc.subjectChemically modified carbon paste electrode-
dc.subjectDifferential pulse anodic stripping voltammetry-
dc.subjectCadmium(II)-
dc.subject1-Furoylthioureas-
dc.titleEvaluation of carbon paste electrodes modified with 1-furoylthioureas for the analysis of cadmium by differential pulse anodic stripping voltammetry-
dc.typeArticle-
Aparece en las colecciones: Doctorado

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
2007S&AB_Thioureas2 2.pdf73.78 kBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.