Por favor, use este identificador para citar o enlazar este ítem:
http://repositoriodigital.ipn.mx/handle/123456789/15735
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | E. Ponce | - |
dc.contributor.author | F.E. Quintela | - |
dc.contributor.author | A. Carballosa | - |
dc.contributor.author | I. Ravelo | - |
dc.contributor.author | T. Flores | - |
dc.date.accessioned | 2013-05-14T19:58:22Z | - |
dc.date.available | 2013-05-14T19:58:22Z | - |
dc.date.issued | 2012-10-16 | - |
dc.identifier.citation | Taller de Emprendedores e Innovación en Ciencia Y Tecnología Fotónica de Latinoamérica page-43. Octubre 16-19, 2012 Tampico, México | es |
dc.identifier.uri | http://www.repositoriodigital.ipn.mx/handle/123456789/15735 | - |
dc.description.abstract | The teeth are in constant chemical attack by microorganisms, which cause visible changes in structure and permanent damage requiring removal of the affected areas. As is known, this procedure is carried out by teams of airotor, causing pain, are invasive and circumferential areas affecting constituents. In recent years the laser has been introduced as a means of removing decay, showing advantages as cleaning, selectivity and decreased pain. An important improvement for these equipments would be having a monitoring system that accurately indicates the kind of tissue being removed. We propose the use of the LIBS (Laser Induced Breakdown Spectroscopy) technique in real time as a method of detection of diseased tissue.The chemical composition of healthy and diseased tissue was been analyzed, establishing clear differences in their elemental compositions and allowing identification of the tissue. The excitation source is a laser device emitting trains of pulses whose intensity and temporal spacing increase the excitation of the chemical species and consequently improve the signal-noise ratio. For its compactness and low cost, the device would be easily integrated to a dental laser system. | es |
dc.description.sponsorship | INSTITUTO POLITECNICO NACIONAL CICATA UNIDAD ALTAMIRA | es |
dc.language.iso | en | es |
dc.publisher | Taller de Emprendedores e Innovación en Ciencia Y Tecnología Fotónica de Latinoamérica page-43. Octubre 16-19, 2012 Tampico, México | es |
dc.subject | El LIBS como método de detección de tejido desmineralizado en dientes | es |
dc.title | El LIBS como método de detección de tejido desmineralizado en dientes | es |
dc.type | Book chapter | es |
dc.description.especialidad | Tecnologia Avanzada | es |
Aparece en las colecciones: | Congresos |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
TIPST-LAT 44.pdf | 220.54 kB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.