dc.descriptionThis paper presents a comparison between of two type of current control to reduce the THDi and increase the PF in a Three-Phase Boost Rectifier driving a small wind turbine. The two types of current controls are peak current mode control and average current mode control It is used as the input stage of small wind turbines with permanent magnet synchronous generators operating at variable speed. The Boost Rectifier output is connected to an inverter which injects the energy to a distribution power grid. The operation in discontinuous conduction mode allows significantly reducing the Total Harmonic Distortion of the current in the small wind turbine.es
dc.description.abstractThis paper presents a comparison between of two type of current control to reduce the THDi and increase the PF in a Three-Phase Boost Rectifier driving a small wind turbine. The two types of current controls are peak current mode control and average current mode control It is used as the input stage of small wind turbines with permanent magnet synchronous generators operating at variable speed. The Boost Rectifier output is connected to an inverter which injects the energy to a distribution power grid. The operation in discontinuous conduction mode allows significantly reducing the Total Harmonic Distortion of the current in the small wind turbine.es
dc.language.isoenes
dc.titleComparison of current control for low harmonic distortion applied to a small wind generation system with permanent magnet synchronous generatores
dc.typeponenciaes
dc.description.especialidadComputaciones
dc.description.tipoPDFes
Aparece en las colecciones: Congresos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
IECON-Comparison of current control for low harmonic distortion applied to a small wind generation system with permanent magnet synchronous generator.pdfComprison of current control for low harmonic distortion applied to a small wind generation system with permanent magnet synchronous generator581.91 kBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.